M0306 MODBUS to DP Module

M0306 MODBUS to DP Module

M0307 MODBUS to PA Module

M0310 MODBUS to HART Module

M0313 MODBUS to FF Module

Modbus-DP built-in module realizes the connection from Modbus RTU device to PROFIBUS DP network .It realizes the conversion function from MODBUS Protocol to PROFIBUS DP Protocol. Only by simply operating Modbus configuration tool, the users can realize connection from Modbus RTU device to PROFIBUS DP network.
M0306 module works with DIP16 2.54mm standard interface, 3.3 V power supply, Modbus communication indicating light to quick diagnosis the device status. It uses simple convenience
Combining with the features of high reliability and high flexibility, M0306 module is an ideal choice for user to develop OEM devices with PROFIBUS DP protocol.

Features
Support 1 Modbus RTU slave device
Comply with standard PROFIBUS-DP/V0
Support Max 244 bytes input data, 244 bytes output data, 360 bytes input output data, 200 bytes user data
Set flexibly Modbus RTU and PROFIBUS DP protocols with GSD file
Transparently transmitting data between Modbus RTU and PROFIBUS DP
Hardware setting of PROFIBUS DP Device Address
Module is suitable for transducer, motor protective device, transmitter, smart field measuring equipment and device with Modbus protocol.

 

Specifications
Working Temperature
-40 °C ... +85 °C
Storage Temperature
-40 °C ... +85 °C
Working Pressure
9 … 36 V, 14 mA @ 24 V
Dimension (L x W x H)
65 x 42 x 14 mm
Interface
TTL
Indicator Light
Rx/Tx, bus-specific
Weight
14 g
Original protocol
Modbus
New protocol
PROFIBUS DP
Electromagnetic compatibility
GB/T 18268.1
Noise immunity
EN 61131-2:2003
Installation
DIP16 2.54mm

 

Modbus-DP built-in module realizes the connection from Modbus RTU device to PROFIBUS DP network .It realizes the conversion function from MODBUS Protocol to PROFIBUS DP Protocol. Only by simply operating Modbus configuration tool, the users can realize connection from Modbus RTU device to PROFIBUS DP network.
M0306 module works with DIP16 2.54mm standard interface, 3.3 V power supply, Modbus communication indicating light to quick diagnosis the device status. It uses simple convenience
Combining with the features of high reliability and high flexibility, M0306 module is an ideal choice for user to develop OEM devices with PROFIBUS DP protocol.

Features
Support 1 Modbus RTU slave device
Comply with standard PROFIBUS-DP/V0
Support Max 244 bytes input data, 244 bytes output data, 360 bytes input output data, 200 bytes user data
Set flexibly Modbus RTU and PROFIBUS DP protocols with GSD file
Transparently transmitting data between Modbus RTU and PROFIBUS DP
Hardware setting of PROFIBUS DP Device Address
Module is suitable for transducer, motor protective device, transmitter, smart field measuring equipment and device with Modbus protocol.

 

Specifications
Working Temperature
-40 °C ... +85 °C
Storage Temperature
-40 °C ... +85 °C
Working Pressure
9 … 36 V, 14 mA @ 24 V
Dimension (L x W x H)
65 x 42 x 14 mm
Interface
TTL
Indicator Light
Rx/Tx, bus-specific
Weight
14 g
Original protocol
Modbus
New protocol
PROFIBUS DP
Electromagnetic compatibility
GB/T 18268.1
Noise immunity
EN 61131-2:2003
Installation
DIP16 2.54mm

 

M0307 realizes the conversion function from Modbus RTU Protocol to PROFIBUS PA Protocol. It connects the slave device with Modbus RTU protocol to PROFIBUS PA network. The M0307 module is the only PROFIBUS PA device that can realize this function in China. All the related configuration is realized through Modbus configuration tool with the features of fastness, flexible, convenient, powerful functionality.M0307 module can be widely used in various fields.

Features
The first company to successfully developed Modbus RTU to PA built-in module in China
Support 1 Modbus RTU slave device
Support the latest PROFIBUS PA 3.02 standard
Support hardware /software setting for PROFIBUS PA Device Address 
The PROFIBUS PA termination is powered by bus power supply
Support as many as four groups of function blocks: AI,AO,DI,DO, each group has four blocks, totally 16 function blocks provided, so it has been leading in the global market of similar products. 
Support GSD file, totally 16 slots provided, each slot is fixed to one function block, which is able to be configured with a variety of modules 
Support EDD file

 

Specifications
Working Temperature
-40 °C ... +85 °C
Storage Temperature
-40 °C ... +85 °C
Working Pressure
9 … 36 V, 14 mA @ 24 V
Dimension (L x W x H)
65 x 42 x 13 mm
Interface
TTL
Indicator Light
Rx/Tx, bus-specific
Weight
16 g
Original protocol
Modbus
New protocol
PROFIBUS PA
Electromagnetic compatibility
GB/T 18268.1
Noise immunity
GB 9254
Installation
DIP16 2.54mm

M0310 module makes it possible to convert Modbus RTU protocol directly to HART protocol. Using M0310 module, the difficulty of development can be reduced and the upgrade of Modbus RTU device can be easily achieved. Only by simply configuration, the users can realize conversion from Modbus RTU protocol to HART protocol. M0310 module is provided with two LED indicating lights, used to indicate the current working status.Features
Support 1 Modbus RTU slave device
1 RES function block complying to FF specification
1 Modbus transducer block
4 PID function blocks complying to FF specification
4 for each AI,AO,DI,DO function block complying to FF specification, each function block supports 8 channels
Modbus RTU device upgrading
LED working status indicator

 

Basic Parameters

Working  Temperature-40℃…+85℃
Storage  Temperature-40℃…+85℃
Working  Pressure12V ... 42V

Outline Size

(L  x W x H)

65mm x 42mm x 15mm
InterfaceTTL
Indicating  LightRx/Tx,  bus-specific
Weight15g
Protocol  before convertModbus
GB/Z 19582.1-2004
Protocol  after convertHART
GB/T 29910.1~.6-2013
EMCGB/T 18268.1
Noise  InterferenceGB  9254
InstallationDIP16 2.54mm

M0313 module makes it possible to convert Modbus RTU protocol directly to FF H1 protocol. Using M0313 module, the difficulty of development can be reduced and the upgrade of Modbus RTU device can be easily achieved. Only by simply configuration, the users can realize conversion from Modbus RTU protocol to FF protocol. M0313 module is provided with two LED indicating lights, used to indicate the current working status.

Features
Support 1 Modbus RTU slave device
1 RES function block complying to FF specification
1 Modbus transducer block
4 PID function blocks complying to FF specification
4 for each AI,AO,DI,DO function block complying to FF specification, each function block supports 8 channels
Modbus RTU device upgrading
LED working status indicator

 

Specifications
Working Temperature
-40 °C ... +85 °C
Storage Temperature
-40 °C ... +85 °C
Working Pressure
9 … 36 V, 14 mA @ 24 V
Dimension (L x W x H)
65 x 42 x 13 mm
Interface
TTL
Indicator Light
Rx/Tx, bus-specific
Weight
16 g
Original protocol
Modbus
New protocol
FF, IEC61158
Electromagnetic compatibility
GB/T 18268.1
Noise immunity
GB 9254
Installation
DIP16 2.54mm

 

TEL:
0086-24-31217278
0086-24-31217280
Fax:
0086 24 31217293
E-MAIL:
jin.guangshu@microcyber.cn
Address:
17-8 Wensu Street, Hunnan New District, Shenyang, China.
Zip:110179